Skip to main content

AS 1670.1:2018 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 1: Fire

Standards Australia

Version:  Fourth Edition 2018.  (Current)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
05-11-2021
Pages
160
Current status
Current
Superseded by

Amended by: AS 1670.1:2018 Amd 1:2021 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 1: Fire

Document Number
1670
Description

This Standard incorporates Amendment No. 1 (July 2021). The start and end of changes introduced by the Amendment are indicated in the text by tags including the amendment number 1.

The objective of this revision is to remove many of the legacy Standards superseded by a number of AS 7240 Standards which have been published since 2004 as well as incorporating some corrections and clarifications.

It has also introduced AS ISO 7240.17 for short circuit isolators and AS ISO 7240.18 for input/output devices to replace the requirements for distributed CIE used with AS 4428.1 systems.

All references to smoke alarms and heat alarms have been removed.

This edition also permits the use of two editions of relevant Standards relating to components. See Table 1.8 for the list of relevant editions of the Standards which apply throughout this document. Notes to clauses in this Standard do not form a mandatory part for conformance with this Standard. They are
of an advisory nature only and are used to give explanation or guidance to the user on recommended considerations or technical procedures, or to provide an informative cross-reference to other documents or publications.

Statements expressed in mandatory terms in notes are deemed to be requirements of this Standard.

The terms “normative” and “informative” have been used in this Standard to define the application of the appendices to which they apply. A “normative” appendix is an integral part of a Standard, whereas an “informative” appendix is for information and guidance.

Originated as part of AS CA15-1961. Previous edition AS 1670.1-1995. AS 1670.1-1995 and AS 1670.2-1997 revised, amalgamated and designated as AS 1670.1-2004. Second edition AS 1670.1:2015. This edition 2018. Reissued incorporating Amendment No 1 (November 2021).

Scope

This Standard sets out requirements for the design, installation and commissioning of fire detection and alarm systems comprising components conforming to the requirements of the appropriate component Standards.

NOTE 1: Where  detection  and  control  and  indicating  equipment  forms  part  of  a  smoke  control  system  in  accordance with AS 1668.1, specific requirements are covered in Clause 7.
NOTE 2: Where detection and control and indicating equipment forms part of a special hazard system in accordance with AS 4214 series, the additional requirements are covered in AS 1670.5 Fire — Special Hazards.
NOTE 3: Maintenance requirements for fire detection and alarm equipment are given in AS 1851.

Contents:

Section 1: Scope And General  
Section 2: System Configuration
Section 3: Installation Requirements
Section 4: Heat Detectors
Section 5: Smoke And Carbon Monoxide (CO) Fire Detectors
Section 6: Flame Detectors
Section 7: Smoke Control Systems
Appendix A: (Informative) Commissioning
Appendix B: (Informative) Wiring Systems  
Appendix C: (Informative) Power Source Calculation Examples  
Appendix D: (Normative) Drawings And Symbols  
Appendix E: (Informative) Designer’s Statement  
Appendix F: (Informative) Installer’s Statement  
Appendix G: (Informative) Commissioning Statement  
Appendix H: (Normative) Sound Pressure Level Measurements  
Appendix I: (Normative) Measurement Of Speech Intelligibility
Appendix J: (Informative) Methods Of Measuring Speech Intelligibility  
Appendix K: (Informative) Lettering Checklist  
Appendix L: (Informative) Recommended Orientation Of Duct Sampling Smoke Detector Probes
Appendix M: (Informative) Guidance For The Selection Of Detectors  
Appendix N: (Informative) ASD Sensitivity Classes  
Amendment Control Sheet

Committee

Fire Detection, Warning, Control and Intercom Systems.

Association of Hydraulic Services Consultants Australia; Australasian Fire and Emergency Service Authorities Council; Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Industry Group; Australian Institute of Building Surveyors; CSIRO; Deafness Forum of Australia; Department of Health and Human Services, Vic.; Engineers Australia; Fire Protection Association Australia; National Electrical and Communications Association; National Fire Industry Association; Property Council of Australia; Society of Fire Safety.

ISBN
978 1 76072 321 7
Attribution
Standards Australia 2018.
Licence
© All Rights Reserved
NSW
VIC
QLD
NT
WA
ACT
TAS
SA
Sector
Residential
Civil
Commercial
Industrial
AS 1670.1:2018 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 1: Fire 2018 cover