AS 2118.2:2021 Automatic fire sprinkler systems, Part 2: Wall wetting sprinkler systems

Standards Australia

Version:  Third Edition 2021.  (Current)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
25-06-2021
Pages
30
Current status
Current
Supersedes

Supersedes: AS 2118.2-2010 Automatic fire sprinkler systems, Part 2: Wall wetting sprinkler systems

Draft Designation: DR AS 2118.2:2020
Document Number
2118
Description

The objective of this document is to provide system designers and installers with a set of requirements for the design, installation and commissioning of wall wetting sprinkler systems to provide protection to the unprotected opening infills of a building subject to the limitations detailed in this document.

NOTE: Atrium protection details are contained in the NCC.

The objective of this revision is to update the type of sprinklers (previously referred to as drenchers) to be installed, including their orientation, to enhance the efficacy of the wall wetting sprinkler system.

The AS 2118 suite of sprinkler Standards is structured into two groups: systems (AS 2118 series) and components (AS 4118 series). A list of all parts in the AS 2118 and AS 4118 series can be found in the Standards Australia online catalogue.

The major changes in this edition are as follows:
(a) Alignment with NCC terminology.
(b) Update to technical equipment in line with recent research testing and results.
(c) Update of design criteria in line with recent research testing and results.
(d) Clarification on the water supply requirements for different applications of this document.
(e) Limit of protection provided by wall wetting sprinklers to 40 kW per m2 in response to recent research testing and results.

The terms “normative” and “informative” are used in Standards to define the application of the appendices to which they apply. A “normative” appendix is an integral part of a Standard, whereas an “informative” appendix is only for information and guidance.

A note to a clause in this document is designed to draw attention to a condition that needs to be considered when applying the clause; for example, a reminder that another Standard needs to be consulted which could conflict with the clause.

A commentary is an explanation as to why the clause was written or developed and is primarily intended to assist with how the clause would be applied in practice.

First published as AS 2118.2-1995. Previous edition 2010. Third edition 2021.
Scope

This document sets out requirements for the design, installation, and commissioning of wall wetting sprinkler systems where the exposure protection requirements of AS 2118.1 do not apply. The requirements are intended to provide automatic external and/or automatic internal protection to the unprotected opening infills of a building.

Contents:

Section 1: Scope And General
Section 2: System Design
Section 3: Water Supplies
Section 4: System Installation And Components Piping
Section 5: Commissioning
Appendix A: Example Of Wall Wetting Sprinkler System Completion Certificate

Committee

Automatic Fire Sprinkler Installations.

Australasian Fire and Emergency Service Authorities Council; Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Institute of Building Surveyors; CSIRO; Department of Health and Human Services, Vic.; Engineers Australia; Exova (Testing Interests Australia); Fire Protection Association Australia; Hydraulic Consultants Association Australasia; Insurance Council of Australia; National Fire Industry Association.

ISBN
978 1 76113 416 6
Attribution
Standards Australia 2021.
Licence
© All Rights Reserved
NSW
VIC
QLD
ACT
SA
WA
NT
TAS
Sector
Residential
Commercial
Civil
Industrial