Skip to main content

AS 2118.8-1997 Automatic fire sprinkler systems, Part 8: Minor modifications

Standards Australia

Version:  First Edition 1997.  (Current)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
05-12-1997
Pages
10
Current status
Current
Supersedes
Draft Designation: DR 96043
Superseded by

Reconfirmed by: AS 2118.8-1997 Rec:2013 Automatic fire sprinkler systems, Part 8: Minor modifications

Document Number
2118
Description

This Standard is the result of a consensus among representatives on the Joint Committee to produce it as an Australian Standard.

The objective of this Standard is to provide requirements to apply when an existing sprinkler system of light or ordinary hazard classification is to be subjected to minor modifications such as the removal, alteration or addition of sprinklers, or the modification or addition of ranges and distribution pipes of limited size.

Product and installation Standards are kept separate. The AS 2118 series, Automatic fire sprinkler systems, and the related series AS 4118, Fire sprinkler systems, comprise the following:

AS
2118 Automatic fire sprinkler systems
Part 1: Standard
Part 2: Wall wetting sprinklers (Drenchers)
Part 3: Deluge
Part 4: Residential
Part 5: Domestic
Part 6: Combined sprinkler and hydrant
Part 8: Minor modifications
Part 9: Piping support and installation
Part 10: Approval documentation

4118 Fire sprinkler systems
Part 1.1: Components — Sprinklers and sprayers
Part 1.2: Components — Alarm valves (wet)
Part 1.3: Components — Water motor alarms
Part 1.4: Components — Valve monitors
Part 1.5: Components — Deluge and pre-action valves
Part 1.6: Components — Stop valves and non-return valves
Part 1.7: Components — Alarm valves (dry)
Part 2.1: Piping — General

Most fire sprinkler systems will undergo minor modifications, especially ordinary hazard systems installed in shopping centres and multistoried office blocks where ongoing changes in tenancy require that changes in the location of walls, partitions, lights, or to the decor require the relocation, addition or deletion of sprinkler heads. It would be uneconomical for the installation design drawings and hydraulic calculations to be fully revised when minor modifications can be done effectively by site personnel possessing a knowledge of the original system design criteria and of the requirements and limitations as set out in this Standard.

This Standard assumes that any existing system intended to be modified, as distinct from the proposed modification, fully complies with the requirements of the Standard to which it was originally designed and installed. In circumstances where the original system does not comply with the appropriate design and installation Standard, the areas which do not comply together with the proposed modifications should be approved by the appropriate regulatory authority prior to commencement of the proposed modification work.

Reconfirmed: 2013-07-11

First published as AS 2118.8-1997.

Scope

This Standard sets out the requirements and limitations pertaining to minor modifications which may be required to existing light hazard and ordinary hazard automatic sprinkler systems only. Modifications to high hazard, wall-wetting, deluge, residential and domestic systems are subject to design analysis before work commences and are not covered by this Standard.

Contents:

Section 1: Scope And General
Section 2: General Requirements
Section 3: Particular Requirements
Section 4: Precautions To Be Taken When A System Is Rendered Inoperative

Committee

Automatic Fire Sprinkler Installations.

Association of Consulting Engineers, Australia; Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Chamber of Manufactures; Australian Fire Authorities Council; Commonwealth Fire Board; Department of Defence (Australia); Fire Protection Association Australia; Institution of Engineers, Australia; Insurance Council of Australia; New Zealand Fire Services; Property Council of Australia; Scientific Services Laboratory; Testing interests.

ISBN
0 7337 1601 6
Attribution
Standards Australia 1997.
Licence
© All Rights Reserved
NSW
VIC
QLD
NT
WA
ACT
TAS
SA
Sector
Residential
Civil
Commercial
Industrial
AS 2118.8-1997 Automatic fire sprinkler systems, Part 8: Minor modifications 1997 cover