Skip to main content

AS 4118.1.5-1996 Fire sprinkler systems, Part 1.5: Components - Deluge and pre-action valves

Standards Australia

Version:  First Edition 1996.  (Current)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
05-01-1996
Pages
22
Current status
Current
Supersedes
Draft Designation: DR 95133
Superseded by

Reconfirmed by: AS 4118.1.5-1996 Rec:2013 Fire sprinkler systems, Part 1.5: Components - Deluge and pre-action valves

Document Number
4118
Description

This Standard is the result of a consensus among representatives on the joint committee to produce it as an Australian Standard.

The revisions to AS 2118 have included Standards Australia’s requirements to keep product and installation Standards separate. When complete the series will comprise the following:

AS 2118 Automatic fire sprinkler systems
Part 1: Standard
Part 2: Wall wetting sprinklers (Drenchers)
Part 3: Deluge
Part 4: Residential
Part 5: Domestic
Part 6: Combined sprinkler and hydrant
Part 9: Piping support and installation
Part 10:Approval documentation

4118 Fire sprinkler systems
Part 1.1: Components — Sprinklers and sprayers
Part 1.2: Components — Alarm valves (wet)
Part 1.3: Components — Water motor alarms
Part 1.4: Components — Valve monitors
Part 1.5: Components — Deluge and pre-action valves
Part 1.6: Components — Stop valves and non-return valves
Part 1.7: Components — Alarm valves (dry)
Part 1.8: Components — Pressure reducing valves
Part 1.9: Components — Accelerators and exhausters
Part 2.1: P iping — General

ISO 6182 has been drawn on for the development of this Standard and the assistance received is hereby acknowledged.

The term s ‘normative’ and ‘informative’ have been used in this Standard to define the application of the appendix to which they apply. A ‘normative’ appendix is an integral part of a Standard, whereas an ‘informative’ appendix is only for information and
guidance.

Reconfirmed: 2013-07-10 First published as AS 4118.1.5-1996.
Scope

This Standard specifies the construction, performance and testing requirements for deluge valves used in deluge and pre-action fire sprinkler systems.

Contents:

Section 1: Scope And General
Section 2: Requirements
Section 3: Test Methods
Section 4: Marking
Section 5: Instruction Charts And Trim

Committee

Components-Deluge and Pre-action Valves.

Asset Services; Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Chamber of Manufactures; Australian Fire Authorities Council; Australian Fire Protection Association; Australian Water and Sewerage Authorities; Commonwealth Fire Board; CSIRO-Division of Building, Construction and Engineering; Department of Defence; Fire Protection Industry Association of Australia; Institution of Engineers, Australia; Insurance Council of Australia; Master Plumbers and Mechanical Services Association of Victoria; Melbourne Water; New Zealand Fire Equipment Association; Telstra, Australia; The Association of Consulting Engineers, Australia.

ISBN
0 7337 0229 5
Attribution
Standards Australia 1996.
Licence
© All Rights Reserved
NSW
VIC
QLD
NT
WA
ACT
TAS
SA
Sector
Residential
Civil
Commercial
Industrial