AS 4654.2-2012 Waterproofing membranes for external above-ground use, Part 2: Design and installation

Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
14-09-2012
Pages
40
Current status
Pending Revision
Document Number
4654
Description

This Standard was prepared by the Standards Australia Committee BD-013, External Waterproofing Membranes, to supersede AS 4654.2—2009 Waterproofing membrane systems for exterior use—Above ground level, Part 2: Design and installation.

This Standard has been prepared in response to numerous requests from industry representatives in the field of external waterproofing, especially in the areas of roofs, decks and balconies.

The objective of this Standard is to provide a consistent and reliable approach to the design and installation of external waterproofing membrane systems.

The objective of this revision is to align this Standard with the protocols and requirements as set out by the Australian Building Codes Board (ABCB).

This Standard is Part 2 of a series of Standards on external waterproofing, as follows:

AS
4654 Waterproofing membranes for external above-ground use
4654.1 Part 1: Materials
4654.2 Part 2: Design and installation (this Standard)

Figures throughout this Standard indicate the membrane system as a heavy dashed layer line. The system may comprise a single layer or multiple layers.

The term ‘informative’ has been used in this Standard to define the application of the appendix to which it applies. An ‘informative’ appendix is only for information and guidance.

Scope

This Standard sets out requirements for the design and installation of above-ground external waterproofing membranes for use in buildings and structures (for example roofs and balconies).

The waterproofing membranes covered by this Standard are also suitable for landscaped areas.

This Standard is not intended for use in applications such as structures below ground level, swimming pools and spas. It excludes concrete admixtures or penetrant sealers and decorative coatings.

Contents:

Section 1: Scope And General
Section 1.1: Scope
Section 1.2: Normative References
Section 1.3: Definitions
Section 1.4: Membrane Systems
Section 1.5: Exposed And Protective Systems
Section 1.6: Conformance Conditions
Section 2: Design And Installation
Section 2.1: General
Section 2.2: Prevention Of Damage
Section 2.3: Movement
Section 2.4: Membranes
Section 2.5: Substrate
Section 2.6: Laying Membrane
Section 2.7: Fillets
Section 2.8: Termination Of Membranes
Section 2.9: Movement And Control Units
Section 2.10: Drains
Section 2.11: Overflows
Section 2.12: Changes In Directions Or Upstands
Section 2.13: Planter Boxes
Section 2.14: Protection During Construction
Section 2.15: Overlaying Surface Finishes
Section 2.16: Inspection And Acceptance Test
Appendix A: Vertical Upward Termination Heights
Appendix B: Maintenance

Author
Standards Australia
Committee

External Waterproofing Membranes.

BD-038

Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Institute of Waterproofing; Australian Tile Council; CSIRO Manufacturing and Infrastructure Technology; Housing Industry Association; Importers Distributors and Sealants Manufacturers Association of Australia; Master Builders Australia; South Australian Housing Trust; TAFE NSW.

ISBN
978 1 74342 226 7
Attribution
Standards Australia 2012.
Licence
© All Rights Reserved
NSW
VIC
QLD
NT
WA
ACT
TAS
SA
Sector
Residential
Civil
Commercial
Industrial
AS 4654.2-2012 Waterproofing membranes for external above-ground use, Part 2: Design and installation 2012 cover