Skip to main content

AS/NZS 5149.1:2016 Refrigerating systems and heat pumps - Safety and environmental requirements, Part 1: Definitions, classification and selection criteria (ISO 5149-1:2014, MOD)

Standards Australia/Standards New Zealand

Version:  Second Edition 2016.  (Current)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
19-07-2018
Pages
76
Current status
Current
Supersedes

Supersedes: AS/NZS 1677.2:1998 Refrigerating systems and heat pumps - Safety and environmental requirements, Part 1: Definitions, classification and selection criteria (ISO 5149-1:2014, MOD)

Draft Designation: DR AS/NZS 5149.1:2016
Superseded by

Amended by: AS/NZS 5149.1:2016 Amd 1:2018 Refrigerating systems and heat pumps - Safety and environmental requirements, Part 1: Definitions, classification and selection criteria (ISO 5149-1:2014, MOD)

Amended by: AS/NZS 5149.1:2016 Amd 2:2018 Refrigerating systems and heat pumps - Safety and environmental requirements, Part 1: Definitions, classification and selection criteria (ISO 5149-1:2014, MOD)

Document Number
5149
Description

This Standard incorporates Amendment No. 1 (March 2018) and No. 2 (July 2018). The changes required by the Amendment are indicated in the text by a marginal bar and amendment number against the clause, note, table, figure or part thereof affected.

The objective of this Standard is to promote the safe design, construction, disposal, installation and operation of refrigerating systems.

This Standard does not address the hazards caused by products of combustion or decomposition of refrigerants. These products may include (but are not limited to) hydrogen fluoride. Exposure to these products can be harmful.

Lubricants and associated hazards are also not covered by this Standard. Lubricants can present significant health and environmental hazards.

AS/NZS 60079.14 is the current Australian/New Zealand Standard on electrical installations design, selection and erection in explosive atmospheres.

The AS/NZS 5149 series consists of the following parts under the general title, Refrigerating systems and heat pumps—Safety and environmental requirements:

Part 1: Definitions, classification and selection criteria (ISO 5149-1:2014, MOD) (this Standard)
Part 2: Design, construction, testing, marking and documentation (ISO 5149-2:2014, MOD)
Part 3: Installation site (ISO 5149-3:2014, MOD)
Part 4: Operation, maintenance, repair and recovery (ISO 5149-4:2014, MOD)

This Standard is an adoption with national modifications and has been reproduced from ISO 5149-1:2014, Refrigerating systems and heat pumps—Safety and environmental requirements, Part 1: Definitions, classification and selection criteria, and its Amendment No. 1 (2015), Correction of QLAV, QLMV, which has been added at the end of the document. This has been varied as indicated to take account of Australian/New Zealand conditions. The modifications are specified in the normative Appendix ZZ following the source text.

These modifications to the ISO source text are essential for compliance with this Australian/New Zealand Standard.

Appendix ZA provides guidance and examples on refrigerant charge limit determination for information only.

This Standard is to be read in conjunction with relevant legislation, regulation and national Refrigeration Industry Codes of Practice.

As this Standard is reproduced from an International Standard, the following applies:
(a) In the source text ‘this International Standard’ should read ‘this Australian/New Zealand Standard’.
(b) A full point substitutes for a comma when referring to a decimal marker.

Only normative references that have an alternative Australian or Australian/New Zealand Standard have been listed.

The terms ‘normative’ and ‘informative’ have been used in this Standard to define the application of the annex or appendix to which they apply. A ‘normative’ annex or appendix is an integral part of a Standard, whereas an ‘informative’ annex or appendix is only for information and guidance.

Originated in Australia as part of AS CB3-1933. Final Australian edition AS 1677-1986. Originated in New Zealand as NZSS 1653:1962. Final New Zealand editions NZS 5235.1:1991 and NZS 5235.2:1988. AS 1677-1986, NZS 5235.1:1991 and NZS 5235.2:1998 jointly revised, amalgamated and redesignated in part as AS/NZS 1677.2:1998. Revised and redesignated in part as AS/NZS 5149.1:2016. Reissued incorporating Amendment No. 1 (March 2018). Reissued incorporating Amendment No. 2 (July 2018).

Committee

Refrigeration.

Air Conditioning and Refrigeration Equipment Manufacturers Association of Australia; Air Conditioning and Refrigeration Wholesalers Association; Australian Industry Group; Australian Institute of Refrigeration, Air Conditioning and Heating; Australian National Retailers Association; Australian Refrigeration Council; Climate Control Companies Association, New Zealand; Consumer Electronics Suppliers Association; Department of Environment; Department of Natural Resources and Mines, Qld; Environmental Protection Authority, New Zealand; Green Cooling Association; Institute of Refrigeration Heating and Air Conditioning Engineers of New Zealand; Metropolitan Fire and Emergency Services Board, Vic.; Ministry of Business, Innovation and Employment, New Zealand; New Zealand Electrotechnical Committee; Refrigerants Australia; Workplace Health and Safety Queensland; WorkSafe New Zealand; WorkSafe Victoria.

ISBN
978 1 76035 583 8
Attribution
Standards Australia/Standards New Zealand 1994.
Licence
© All Rights Reserved
NSW
VIC
QLD
NT
WA
ACT
TAS
SA
Sector
Residential
Civil
Commercial
Industrial
AS/NZS 5149.1:2016 Refrigerating systems and heat pumps - Safety and environmental requirements, Part 1: Definitions, classification and selection criteria (ISO 5149-1:2014, MOD) 1994 cover