Skip to main content

AS 2118.4-2012 Automatic fire sprinkler systems, Part 4: Sprinkler protection for accommodation buildings not exceeding four storeys in height

Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
error_outline
You are currently viewing a preview version of this resource. Sign in or subscribe for full access.
Publication date
22-05-2012
Pages
52
Current status
Pending Revision
Supersedes
Document Number
2118
Description

Sprinkler Standards consist of two groups: Systems (AS 2118 series) and Components (AS 4118 series). The complete series comprises the following:

AS
2118 Automatic fire sprinkler systems
2118.1 Part 1: General systems
2118.2 Part 2: Drencher systems
2118.3 Part 3: Deluge systems
2118.4 Part 4: Sprinkler protection for accommodation buildings not exceeding four storeys in height (this Standard)
2118.5 Part 5: Home fire sprinkler systems
2118.6 Part 6: Combined sprinkler and hydrant
4118 Fire sprinkler systems
4118.1.1 Part 1.1: Components—Sprinklers and sprayers
4118.1.2 Part 1.2: Components—Alarm valves (wet)
4118.1.3 Part 1.3: Components—Water motor alarms
4118.1.4 Part 1.4: Components—Valve monitors
4118.1.5 Part 1.5: Components—Deluge and pre-action valves
4118.1.6 Part 1.6: Components—Stop valves and non-return valves
4118.1.7 Part 1.7: Components—Alarm valves (dry)
4118.1.8 Part 1.8: Components—Pressure-reducing valves
4118.2.1 Part 2.1: Piping—General

Changes to the previous (1995) edition of this Standard include the following:

(a) The water supply section has been expanded.
(b) A minimum design flow is specified.
(c) Design criteria for ancillary areas have been revised.
(d) Detailed sprinkler spacing and positioning requirements are included particularly related to obstructions, heat sources and sloped ceilings.
(e) Acceptance testing (commissioning) requirements are detailed.

Wall wetting sprinklers (drenchers) cannot be incorporated in sprinkler systems covered by this Standard. The requirements for such systems are addressed in AS 2118.2.

The terms ‘normative’ and ‘informative’ have been used in this Standard to define the application of the appendix to which they apply. A ‘normative’ appendix is an integral part of a Standard, whereas an ‘informative’ appendix is only for information and guidance.

The use of Notes in this Standard is of an advisory nature only. They provide explanations and guidance on recommended design consideration or technical procedures, as well as an informative cross-reference to other documents or publications.

Originated as AS 2118.4-1995. Second edition 2012.

Scope

The purpose of the Standard is to provide design, installation and acceptance testing (commissioning) criteria for sprinkler systems to aid in the detection and control of fires in
accommodation buildings.

A sprinkler system designed and installed in accordance with this Standard is expected to prevent flashover (total involvement) in the room or area of fire origin, and to improve the chance for occupants to escape or be evacuated.

In preparing this Standard, the Committee considered the US National Fire Protection  Association (NFPA) publication 13R, Standard for the Installation of Sprinkler Systems in Residential Occupancies up to Four Stories in Height, and the assistance gained from this source is acknowledged.

Contents:

Foreword  
Section 1: Scope And General
Section 2: Installation
Section 3: Water Supplies
Section 4: Design And Hydraulics
Section 5: Components
Section 6: Acceptance Testing
Appendix A: Completion Certificate

Committee

Automatic Fire Sprinklers.

Association of Consulting Engineers Australia; Australasian Fire and Emergency Service Authorities Council; Australian Building Codes Board; Australian Industry Group; Australian Institute of Building Surveyors; Consumers' Federation of Australia; Department of Defence (Australia); Department of Human Services (Victoria); Engineers Australia; Fire Protection Association Australia; Independent Chairperson; Insurance Council of Australia; National Fire Industry Association; Testing Interests (Australia).

ISBN
978 1 74342 099 7
Attribution
Standards Australia 2012.
Licence
© All Rights Reserved
NSW
VIC
QLD
NT
WA
ACT
TAS
SA
Sector
Residential
Civil
Commercial
Industrial
AS 2118.4-2012 Automatic fire sprinkler systems, Part 4: Sprinkler protection for accommodation buildings not exceeding four storeys in height 2012 cover