Skip to main content

Search all content

1 - 10 of 59 results
AS 4200.1:2017 Pliable building membranes and underlays, Part 1: Materials 2017 cover

Publisher
Standards Australia

Version:  Second Edition 2017.  (Current)
Short Description
Sets out requirements for materials for use as pliable building membranes (also known as sarking or underlay), when used either independently or as a facing to other materials, such as insulation materials, and as control functions for water, thermal vapour or air control.
AS 5637.1:2015 Determination of fire hazard properties, Part 1: Wall and ceiling linings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 1905.1:2015 Components for the protection of openings in fire-resistant walls, Part 1: Fire-resistant doorsets 2015 cover

Publisher
Standards Australia

Version:  Sixth Edition 2015.  (Current)
Short Description
Sets out requirements for the construction and installation of fire-resistant doorsets that are used to protect openings in walls, and for partitions that are required to resist the passage of fire.
AS 4200.2:2017 Pliable building membranes and underlays, Part 2: Installation 2017 cover

Publisher
Standards Australia

Version:  Third Edition 2017.  (Current)
Short Description
Sets out requirements for the installation of pliable building membranes (also known as ‘sarking’ or ‘underlay’), when used either independently or as a facing to other materials, such as insulation materials, for water control, thermal control, vapour control or air control, or a combination of these control functions.
AS 1530.1-1994 Methods for fire tests on building materials, components and structures, Part 1: Combustibility test for materials 1994 cover

Publisher
Standards Australia

Version:  Third Edition 1994.  (Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.
AS 4072.1-2005 Components for the protection of openings in fire-resistant separating elements, Part 1: Service penetrations and control joints 2005 cover

Publisher
Standards Australia

Version:  Second Edition 2005.  (Current)
Short Description
Specifies requirements for the testing, interpretation of test results, and installation of penetration sealing systems and control joints sealing systems in fire-resistant elements of construction.
AS 5008-2007 Hygienic rendering of animal products 2007 cover

Publisher
Standards Australia

Version:  Second Edition 2007.  (Pending Revision)
Short Description
Provides minimum requirements for construction, equipment and rendering operations prescribed in this Standard.
AS 5010-2001 Hygienic production of ratite (emu/ostrich) meat for human consumption 2001 cover

Publisher
Standards Australia

Version:  First Edition 2001.  (Current)
Short Description
Sets out requirements for the hygienic production of ratite (emu/ostrich) meat for human consumption.