Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
First Edition 2015.
(Current)
Short Description
Sets out minimum requirements for the design, construction, installation and commissioning of mechanical smoke control systems in buildings; specific methods of smoke control are defined and the appropriate requirements specified for each.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Second Edition 2017.
(Current)
Short Description
Sets out requirements for materials for use as pliable building membranes (also known as sarking or underlay), when used either independently or as a facing to other materials, such as insulation materials, and as control functions for water, thermal vapour or air control.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
First Edition 2015.
(Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Second Edition 2014.
(Current)
Short Description
Specifies the criteria for assessing the effectiveness of termite management systems intended for use in buildings and structures as required by AS 3660.1 or AS 3660.2; also outlines procedures to assess the ability of a system and its components to manage termite activity in and around buildings and structures.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
First Edition 1997.
(Current)
Short Description
Sets out the procedure for determining the resistance of a soil to penetration by a flat ended rod of 16 ±0.2 mm diameter driven with a 9 kg mass, dropping 600 mm; use of the method is limited to granular soils with a maximum particle size not exceeding 2 mm, and a layer thickness of at least of 450 mm.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Third Edition 1986.
(Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Third Edition 2012.
(Pending Revision)
Short Description
Specifies requirements for the design, construction and performance of barriers that will restrict the access of young children to swimming pools.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Sixth Edition 2015.
(Current)
Short Description
Sets out requirements for the construction and installation of fire-resistant doorsets that are used to protect openings in walls, and for partitions that are required to resist the passage of fire.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Third Edition 2017.
(Current)
Short Description
Sets out requirements for the installation of pliable building membranes (also known as ‘sarking’ or ‘underlay’), when used either independently or as a facing to other materials, such as insulation materials, for water control, thermal control, vapour control or air control, or a combination of these control functions.
Type
Publisher
Standards Australia
Publisher
Standards Australia
Version:
Third Edition 1994.
(Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.