Skip to main content

Search all content

31 - 40 of 42 results
NCC 2019 Volume 3 Amendment 1

Publisher
Australian Building Codes Board

Version:  2019 Am 1  (Superseded)
Short Description
Covering the design, construction and maintenance of plumbing and drainage systems in new and existing buildings.
NCC 2016 Consolidated Performance Requirements 2018 cover

Publisher
Australian Building Codes Board

Version:  2018.  (Superseded)
Short Description
Provides a compilation of all NCC Performance Requirements and the supporting General Requirements.
NCC 2019 Volume 2 Amendment 1

Publisher
Australian Building Codes Board

Version:  2019 Am 1  (Superseded)
Short Description
Covering the design and construction of smaller scale buildings including houses, small sheds, carports and some associated structures.
AS/NZS 3760:2010 In-service safety inspection and testing of electrical equipment 2010 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Fifth Edition 2010.  (Superseded)
Short Description
Specifies procedures for the safety inspection and testing of low voltage single phase and polyphase electrical equipment, connected to the electrical supply by a flexible cord or connecting device. It also include procedures for the safety inspection and testing of: Residual current devices (RCDs) except those within the scope of AS/NZS 3003 and NZS 6115; and Portable inverters that generate or produce low voltage.
AS/NZS 4836:2011 Safe working on or near low-voltage electrical installations and equipment 2011 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2011.  (Available Superseded)
Short Description
Provides workers on low-voltage electrical installations with: (a) the principles of safe working practices; and (b) recommended procedures for safe working practices.
AS/NZS 1768:2007 Lightning protection 2007 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2007.  (Available Superseded)
Short Description
​Provides guidelines for the protection of persons and property from the hazards of lightning. Applies to conventional lightning protection systems consisting of air terminations, downconductors, earthing systems and surge protective devices. Also provides a comprehensive risk management process for the determination of the risk of damage due to lightning for a range of structures.
NCC 2016 Volume Three 2016 cover

Publisher
Australian Building Codes Board

Version:  2016.  (Superseded)
Short Description
The NCC is a uniform set of technical provisions for the design and construction of buildings and other structures, and plumbing and drainage systems throughout Australia. It allows for variations in climate and geological or geographic conditions.
NCC 2016 Volume Two 2016 cover

Publisher
Australian Building Codes Board

Version:  2016.  (Superseded)
Short Description
Contains the requirements for: Class 1 and 10a buildings, and certain Class 10b structures, and Class 10c private bushfire shelters.
AS/NZS 3001.2:2022 Electrical installations - Connectable electrical installations and supply arrangements, Part 2: Connectable electrical installations 2022 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2022.  (Current)
Short Description
Specifies requirements for electrical installations associated with connectable electrical installations used for the purposes of accommodation, habitation or other residential, commercial purposes or recreational uses that are intended for connection to external low voltage a.c. supply systems (i.e. 50 V a.c. to 1000 V a.c.) by either a detachable supply lead or a supply lead directly connected to the connectable electrical installation; includes requirements and provides guidance for the installation of extra-low voltage systems (i.e. less than 50 V a.c. or 120 V d.c. ripple free).
AS/NZS 3001.1:2022 Electrical installations - Connectable electrical installations and supply arrangements, Part 1: Site supplies for connectable electrical installations 2022 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2022.  (Current)
Short Description
Sets out requirements for electrical installations associated with site supplies for connectable electrical installations that are intended for connection to low voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).