Skip to main content

Search all content

1 - 10 of 14 results
AS 5637.1:2015 Determination of fire hazard properties, Part 1: Wall and ceiling linings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 1530.1-1994 Methods for fire tests on building materials, components and structures, Part 1: Combustibility test for materials 1994 cover

Publisher
Standards Australia

Version:  Third Edition 1994.  (Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.
AS 1530.4:2014 Methods for fire tests on building materials, components and structures, Part 4: Fire-resistance tests for elements of construction 2014 cover

Publisher
Standards Australia

Version:  Sixth Edition 2014.  (Current)
Short Description
Sets out test procedures and criteria for the determination of fire-resistance of elements of building construction.
AS 1905.2-2005 Components for the protection of openings in fire-resistant walls, Part 2: Fire-resistant roller shutters 2005 cover

Publisher
Standards Australia

Version:  Fourth Edition 2005.  (Current)
Short Description
Specifies requirements for design, construction and installation of vertically operating roller shutters intended to protect trafficable openings in fire-rated walls; compliance is based on prototype testing in accordance with AS 1530.4; labelling requirements are included.
AS 3959:2018 Amd 1:2019 Construction of buildings in bushfire-prone areas 2019 cover

Publisher
Standards Australia

Version:  Fourth Edition 2019.  (Current)
Short Description
The 2018 edition of AS 3959 is amended as follows; the amendments should be inserted in the appropriate places.
AS 3959:2018 Amd 2:2020 Construction of buildings in bushfire-prone areas 2018 cover

Publisher
Standards Australia

Version:  Fourth Edition 2020.  (Current)
Short Description
The 2018 edition of AS 3959 is amended as follows; the amendments should be inserted in the appropriate places.
AS 1170.4-2007 Structural design actions, Part 4: Earthquake actions in Australia 2007 cover

Publisher
Standards Australia

Version:  Second Edition 2007.  (Current)
Short Description
Sets out data and procedures for determining earthquake loads on structures and their components, and also minimum detailing requirements for structures; domestic structures are covered in an Appendix.
AS 1530.8.1:2018 Methods for fire tests on building materials, components and structures, Part 8.1: Tests on elements of construction for buildings exposed to simulated bushfire attack - Radiant heat and small flaming sources 2018 cover

Publisher
Standards Australia

Version:  Second Edition 2018.  (Current)
Short Description
This Standard provides methods for determining the performance of external construction elements when exposed to radiant heat, burning embers and burning debris.