Skip to main content

Search all content

1 - 10 of 17 results
AS 5637.1:2015 Determination of fire hazard properties, Part 1: Wall and ceiling linings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 1530.1-1994 Methods for fire tests on building materials, components and structures, Part 1: Combustibility test for materials 1994 cover

Publisher
Standards Australia

Version:  Third Edition 1994.  (Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.
AS 1530.4:2014 Methods for fire tests on building materials, components and structures, Part 4: Fire-resistance tests for elements of construction 2014 cover

Publisher
Standards Australia

Version:  Sixth Edition 2014.  (Current)
Short Description
Sets out test procedures and criteria for the determination of fire-resistance of elements of building construction.
AS 2870-2011 Residential slabs and footings 2011 cover

Publisher
Standards Australia

Version:  Fourth Edition 2011.  (Pending Revision)
Short Description
Sets out requirements for the classification of a site and the design and construction of a footing system for a single dwelling house, town house or the like which may be detached or separated by a party wall or common wall but not situated vertically above or below another dwelling.
AS 3610-1995 Formwork for concrete 1995 cover

Publisher
Standards Australia

Version:  Second Edition 1995.  (Current)
Short Description
Specifies requirements for the design, fabrication, erection and stripping of formwork as well as the evaluation and repair of the formed concrete surface; colour evaluation charts are included in an Appendix.
AS 3610.1:2018 Formwork for concrete, Part 1: Specifications 2018 cover

Publisher
Standards Australia

Version:  Second Edition 2018.  (Current)
Short Description
Sets out (a) the requirements for the documentation of architectural, structural and construction information necessary for formwork design and construction; (b) architectural requirements and procedures covering the specification of the quality, tolerance, colour, and evaluation of off-form or as-repaired in situ or precast concrete surfaces; and (c) structural requirements that- (i) are critical to the stability, strength and serviceability of the permanent structure during construction and once completed; and (ii) affect the formwork design and construction.
AS 1905.2-2005 Components for the protection of openings in fire-resistant walls, Part 2: Fire-resistant roller shutters 2005 cover

Publisher
Standards Australia

Version:  Fourth Edition 2005.  (Current)
Short Description
Specifies requirements for design, construction and installation of vertically operating roller shutters intended to protect trafficable openings in fire-rated walls; compliance is based on prototype testing in accordance with AS 1530.4; labelling requirements are included.
AS 5113:2016 Classification of external walls of buildings based on reaction-to-fire performance 2016 cover

Publisher
Standards Australia

Version:  First Edition 2016.  (Current)
Short Description
Sets out the procedures for the assessment and classification of external walls of buildings according to their tendency to spread fire via the building façade.