Skip to main content

Search all content

1 - 10 of 87 results
AS 1668.1:2015 The use of ventilation and air conditioning in buildings, Part 1: Fire and smoke control in buildings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out minimum requirements for the design, construction, installation and commissioning of mechanical smoke control systems in buildings; specific methods of smoke control are defined and the appropriate requirements specified for each.
AS 4200.1:2017 Pliable building membranes and underlays, Part 1: Materials 2017 cover

Publisher
Standards Australia

Version:  Second Edition 2017.  (Current)
Short Description
Sets out requirements for materials for use as pliable building membranes (also known as sarking or underlay), when used either independently or as a facing to other materials, such as insulation materials, and as control functions for water, thermal vapour or air control.
AS/NZS 3666.1:2011 Air-handling and water systems of buildings - Microbial control, Part 1: Design, installation and commissioning 2011 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Third Edition 2011.  (Pending Revision)
Short Description
Specifies minimum requirements for the design, installation and commissioning of air-handling and water systems of buildings for the purposes of microbial control. It does not include requirements for refrigerated room airconditioners and non-ducted split systems.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 4200.2:2017 Pliable building membranes and underlays, Part 2: Installation 2017 cover

Publisher
Standards Australia

Version:  Third Edition 2017.  (Current)
Short Description
Sets out requirements for the installation of pliable building membranes (also known as ‘sarking’ or ‘underlay’), when used either independently or as a facing to other materials, such as insulation materials, for water control, thermal control, vapour control or air control, or a combination of these control functions.
AS 1668.4-2012 The use of ventilation and airconditioning in buildings, Part 4: Natural ventilation of buildings 2012 cover

Publisher
Standards Australia

Version:  Fourth Edition 2012.  (Pending Revision)
Short Description
Sets out minimum design requirements for natural ventilation systems that ventilate enclosures and requirements for the ventilation of car parks.
AS 5008-2007 Hygienic rendering of animal products 2007 cover

Publisher
Standards Australia

Version:  Second Edition 2007.  (Pending Revision)
Short Description
Provides minimum requirements for construction, equipment and rendering operations prescribed in this Standard.
AS 5010-2001 Hygienic production of ratite (emu/ostrich) meat for human consumption 2001 cover

Publisher
Standards Australia

Version:  First Edition 2001.  (Current)
Short Description
Sets out requirements for the hygienic production of ratite (emu/ostrich) meat for human consumption.
AS 4464-2007 Hygienic production of wild game meat for human consumption 2007 cover

Publisher
Standards Australia

Version:  Second Edition 2007.  (Current)
Short Description
Sets out requirements for hygienic production and transportation of wild game meat for human consumption. This Standard was developed by the Meat Standards Committee (MSC) of the Food Regulation Standing Committee (FRSC) under the Australian and New Zealand Food Regulation Ministerial Council (ANZFRMC). It is also known as FRSC Technical Report No. 2 which was published as AS 4464-2007 by CSIRO PUBLISHING.
AS/NZS 1260:2017 PVC-U pipes and fittings for drain, waste and vent applications 2017 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Fifth Edition 2017.  (Current)
Short Description
Specifies requirements for PVC-U pipes and fittings for sewer, drain, waste and vent applications above ground or below ground and is intended to be used where the pipeline is operating under gravity flow and the operating pressure is low; includes requirements for both plain and structured wall pipes and fittings.