AS 5637.1:2015 Determination of fire hazard properties, Part 1: Wall and ceiling linings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 1530.1-1994 Methods for fire tests on building materials, components and structures, Part 1: Combustibility test for materials 1994 cover

Publisher
Standards Australia

Version:  Third Edition 1994.  (Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.
AS 1530.4:2014 Methods for fire tests on building materials, components and structures, Part 4: Fire-resistance tests for elements of construction 2014 cover

Publisher
Standards Australia

Version:  Sixth Edition 2014.  (Current)
Short Description
Sets out test procedures and criteria for the determination of fire-resistance of elements of building construction.
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location 2001 cover

Publisher
Standards Australia

Version:  Sixth Edition 2001.  (Current)
Short Description
Specifies the criteria for the selection of portable fire extinguishers and the requirements for their application, location and distribution.
AS 2870-2011 Residential slabs and footings 2011 cover

Publisher
Standards Australia

Version:  Fourth Edition 2011.  (Pending Revision)
Short Description
Sets out requirements for the classification of a site and the design and construction of a footing system for a single dwelling house, town house or the like which may be detached or separated by a party wall or common wall but not situated vertically above or below another dwelling.
AS 1670.3:2018 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 3: Fire alarm monitoring 2018 cover

Publisher
Standards Australia

Version:  Fourth Edition 2018.  (Current)
Short Description
Specifies the requirements for fire alarm monitoring systems between the monitored fire detection and alarm system and the fire dispatch centre and includes requirements for the monitoring equipment.
AS 1670.4:2018 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 4: Emergency warning and intercom systems 2018 cover

Publisher
Standards Australia

Version:  Third Edition 2018.  (Current)
Short Description
Specifies the design, installation and commissioning requirements for emergency warning systems and emergency intercom systems used in buildings for the evacuation of building occupants in the event of a fire or other type of emergency.
AS/NZS 1530.3:1999 Methods for fire tests on building materials, components and structures, Part 3: Simultaneous determination of ignitability, flame propagation, heat release and smoke release 1999 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 1999.  (Current)
Short Description
Describes a single test method for grading building materials on the basis of ignition tendency, flame spread, heat development and tendency to produce smoke.