Skip to main content

Search all content

1 - 10 of 17 results
AS 5637.1:2015 Determination of fire hazard properties, Part 1: Wall and ceiling linings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 1530.1-1994 Methods for fire tests on building materials, components and structures, Part 1: Combustibility test for materials 1994 cover

Publisher
Standards Australia

Version:  Third Edition 1994.  (Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.
AS 1668.4-2012 The use of ventilation and airconditioning in buildings, Part 4: Natural ventilation of buildings 2012 cover

Publisher
Standards Australia

Version:  Fourth Edition 2012.  (Pending Revision)
Short Description
Sets out minimum design requirements for natural ventilation systems that ventilate enclosures and requirements for the ventilation of car parks.
AS 1530.4:2014 Methods for fire tests on building materials, components and structures, Part 4: Fire-resistance tests for elements of construction 2014 cover

Publisher
Standards Australia

Version:  Sixth Edition 2014.  (Current)
Short Description
Sets out test procedures and criteria for the determination of fire-resistance of elements of building construction.
AS 4254.2-2012 Ductwork for air-handling systems in buildings, Part 2: Rigid duct 2012 cover

Publisher
Standards Australia

Version:  First Edition 2012.  (Pending Revision)
Short Description
Sets out requirements for materials, construction, and installation, including some aspects of performance, for ductwork for air-handling systems in buildings and facilities, including systems designed in accordance with requirements of AS/NZS 1668.1 and AS 1668.2.
AS 3999:2015 Bulk thermal insulation - Installation 2015 cover

Publisher
Standards Australia

Version:  Second Edition 2015.  (Current)
Short Description
Sets out requirements on installing insulation in both new dwellings during construction and the retrofitting of insulation in existing buildings.
AS 1905.2-2005 Components for the protection of openings in fire-resistant walls, Part 2: Fire-resistant roller shutters 2005 cover

Publisher
Standards Australia

Version:  Fourth Edition 2005.  (Current)
Short Description
Specifies requirements for design, construction and installation of vertically operating roller shutters intended to protect trafficable openings in fire-rated walls; compliance is based on prototype testing in accordance with AS 1530.4; labelling requirements are included.
AS 5113:2016 Classification of external walls of buildings based on reaction-to-fire performance 2016 cover

Publisher
Standards Australia

Version:  First Edition 2016.  (Current)
Short Description
Sets out the procedures for the assessment and classification of external walls of buildings according to their tendency to spread fire via the building façade.