AS/NZS 2107:2016 Acoustics - Recommended design sound levels and reverberation times for building interiors 2016 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2016.  (Current)
Short Description
Recommends design criteria for conditions affecting the acoustic environment within building interiors to ensure a healthy, comfortable and productive environment for the occupants and the users.
AS 1191-2002 Acoustics - Method for laboratory measurement of airborne sound transmission insulation of building elements 2002 cover

Publisher
Standards Australia

Version:  Third Edition 2002.  (Current)
Short Description
Provides a method for the measurement of airborne sound reduction index to building partitions such as walls, floor/ceiling assemblies, doors, windows and other space dividing elements.
Whole-of-Home Efficiency Factors Standard 2022

Publisher
Australian Building Codes Board

Version:  2022.  (Latest)
Short Description
This ABCB Standard provides WOH efficiency factors for Class 1 dwellings, Class 2 sole-occupancy units and Class 4 parts of buildings in the energy efficiency provisions of the NCC; It applies in each NCC climate zone and jurisdiction.
Livable Housing Design Standard 2022 cover

Publisher
Australian Building Codes Board

Version:  2022.  (Latest)
Short Description
Provides a set of technical provisions that if complied with will enable dwellings to better meet the needs of the community, including older people and people with mobility limitations
Fire Safety Verification Method Standard 2022 cover

Publisher
Australian Building Codes Board

Version:  2022.  (Latest)
Short Description
Provides a process for engineering the design of fire safety Performance Solutions. The document provides the flexibility required to develop Performance Solutions while still maintaining the level of safety required by the NCC.
AS ISO 717.2-2004 Acoustics - Rating of sound insulation in buildings and of building elements, Part 2: Impact sound insulation 2004 cover

Publisher
Standards Australia

Version:  First Edition 2004.  (Pending Revision)
Short Description
Defines and provides methods for determining single number quantities for the impact sound insulation in buildings; this Standard is identical with and reproduced from ISO 717-2:1996.
AS 4654.2-2012 Waterproofing membranes for external above-ground use, Part 2: Design and installation 2012 cover

Publisher
Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
Short Description
Sets out a consistent and reliable approach to the design and installation of external waterproofing membrane systems.
ABCB Housing Provisions Standard 2022 cover

Publisher
Australian Building Codes Board

Version:  2022.  (Latest)
Short Description
Contains Deemed-to-Satisfy Provisions that are considered to be acceptable forms of construction that meet the requirements for complying with Parts H1 to H8 of NCC Volume Two.
AS 1288:2021 Glass in buildings - Selection and installation 2021 cover

Publisher
Standards Australia

Version:  Fifth Edition 2021.  (Current)
Short Description
Sets out procedures for the selection and installation of glass in buildings, subject to wind loading, human impact, and special applications. Glass strength is specified, based on the tensile stresses on the surface of the glass.
Resilient Homes Fund: Building industry fact sheet. Quoting and contracting resilience works (for licensed contractors) 2023 cover

Publisher
Queensland Government

Version:  2023.  (Current)
Short Description
Flood resilient design is one of the many ways Queenslanders can build their resilience to floods.