Skip to main content

Search all content

1 - 10 of 16 results
AS 2118.6-2012 Automatic fire sprinkler systems, Part 6: Combined sprinkler and hydrant systems in multistorey buildings 2012 cover

Publisher
Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
Short Description
Sets out minimum criteria for the design, installation and commissioning of combined sprinkler and hydrant systems (including fire hose reels where appropriate) in multistorey buildings greater than two storeys in height.
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location 2001 cover

Publisher
Standards Australia

Version:  Sixth Edition 2001.  (Current)
Short Description
Specifies the criteria for the selection of portable fire extinguishers and the requirements for their application, location and distribution.
AS 2118.5-2008 Automatic fire sprinkler systems, Part 5: Home fire sprinkler systems 2008 cover

Publisher
Standards Australia

Version:  Second Edition 2008.  (Current)
Short Description
Specifies requirements for the design, installation, commissioning and maintenance of automatic fire sprinkler systems for one and two family homes.
AS 2118.8-1997 Automatic fire sprinkler systems, Part 8: Minor modifications 1997 cover

Publisher
Standards Australia

Version:  First Edition 1997.  (Current)
Short Description
Sets out requirements covering minor modifications to existing sprinkler systems of light or ordinary hazard classification, such as the removal, alteration or addition of sprinklers, or the modification or addition of ranges and distribution pipes of limited size.
AS 2118.4-2012 Automatic fire sprinkler systems, Part 4: Sprinkler protection for accommodation buildings not exceeding four storeys in height 2012 cover

Publisher
Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
Short Description
Specifies requirements for the design, installation and acceptance testing (commissioning) of automatic fire sprinkler systems in accommodation buildings not more than four storeys.
AS/NZS ISO 717.1:2004 Acoustics - Rating of sound insulation in buildings and of building elements, Part 1: Airborne sound insulation 2004 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2004.  (Pending Revision)
Short Description
Provides a method whereby the frequency dependent values of airborne sound insulation of building elements and in building can be converted into a single number characterizing the acoustical performance; this Standard is identical with and reproduced from ISO 717-1:1996.
AS/NZS 2107:2016 Acoustics - Recommended design sound levels and reverberation times for building interiors 2016 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2016.  (Current)
Short Description
Recommends design criteria for conditions affecting the acoustic environment within building interiors to ensure a healthy, comfortable and productive environment for the occupants and the users.
AS ISO 717.2-2004 Acoustics - Rating of sound insulation in buildings and of building elements, Part 2: Impact sound insulation 2004 cover

Publisher
Standards Australia

Version:  First Edition 2004.  (Pending Revision)
Short Description
Defines and provides methods for determining single number quantities for the impact sound insulation in buildings; this Standard is identical with and reproduced from ISO 717-2:1996.
AS 1191-2002 Acoustics - Method for laboratory measurement of airborne sound transmission insulation of building elements 2002 cover

Publisher
Standards Australia

Version:  Third Edition 2002.  (Current)
Short Description
Provides a method for the measurement of airborne sound reduction index to building partitions such as walls, floor/ceiling assemblies, doors, windows and other space dividing elements.