AS 5637.1:2015 Determination of fire hazard properties, Part 1: Wall and ceiling linings 2015 cover

Publisher
Standards Australia

Version:  First Edition 2015.  (Current)
Short Description
Sets out procedures for the assessment of internal wall and ceiling linings according to their tendency to ignite; their tendency to release heat once ignition has occurred; their tendency to cause flashover; their tendency to release smoke; and their contribution to fire growth.
AS 1735.11-1986 SAA Lift Code, Part 11: Fire-rated landing doors 1986 cover

Publisher
Standards Australia

Version:  Third Edition 1986.  (Current)
Short Description
Sets out requirements for fire-rated landing doors for retarding the passage of fire through openings in fire-rated liftwells; it applies where doors are required to have a fire-rating certificate.
AS 1530.1-1994 Methods for fire tests on building materials, components and structures, Part 1: Combustibility test for materials 1994 cover

Publisher
Standards Australia

Version:  Third Edition 1994.  (Current)
Short Description
Sets out a test method for determining the combustibility of building materials and is one of a series of test methods for evaluating the potential fire hazard of building products.
AS 2118.6-2012 Automatic fire sprinkler systems, Part 6: Combined sprinkler and hydrant systems in multistorey buildings 2012 cover

Publisher
Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
Short Description
Sets out minimum criteria for the design, installation and commissioning of combined sprinkler and hydrant systems (including fire hose reels where appropriate) in multistorey buildings greater than two storeys in height.
AS 1530.4:2014 Methods for fire tests on building materials, components and structures, Part 4: Fire-resistance tests for elements of construction 2014 cover

Publisher
Standards Australia

Version:  Sixth Edition 2014.  (Current)
Short Description
Sets out test procedures and criteria for the determination of fire-resistance of elements of building construction.
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location 2001 cover

Publisher
Standards Australia

Version:  Sixth Edition 2001.  (Current)
Short Description
Specifies the criteria for the selection of portable fire extinguishers and the requirements for their application, location and distribution.
AS 2118.5-2008 Automatic fire sprinkler systems, Part 5: Home fire sprinkler systems 2008 cover

Publisher
Standards Australia

Version:  Second Edition 2008.  (Current)
Short Description
Specifies requirements for the design, installation, commissioning and maintenance of automatic fire sprinkler systems for one and two family homes.
AS 2118.8-1997 Automatic fire sprinkler systems, Part 8: Minor modifications 1997 cover

Publisher
Standards Australia

Version:  First Edition 1997.  (Current)
Short Description
Sets out requirements covering minor modifications to existing sprinkler systems of light or ordinary hazard classification, such as the removal, alteration or addition of sprinklers, or the modification or addition of ranges and distribution pipes of limited size.
AS 2118.4-2012 Automatic fire sprinkler systems, Part 4: Sprinkler protection for accommodation buildings not exceeding four storeys in height 2012 cover

Publisher
Standards Australia

Version:  Second Edition 2012.  (Pending Revision)
Short Description
Specifies requirements for the design, installation and acceptance testing (commissioning) of automatic fire sprinkler systems in accommodation buildings not more than four storeys.