Skip to main content

Search all content

61 - 70 of 103 results
AS 3959:2018 Amd 1:2019 Construction of buildings in bushfire-prone areas 2019 cover

Publisher
Standards Australia

Version:  Fourth Edition 2019.  (Current)
Short Description
The 2018 edition of AS 3959 is amended as follows; the amendments should be inserted in the appropriate places.
AS 3959:2018 Amd 2:2020 Construction of buildings in bushfire-prone areas 2018 cover

Publisher
Standards Australia

Version:  Fourth Edition 2020.  (Current)
Short Description
The 2018 edition of AS 3959 is amended as follows; the amendments should be inserted in the appropriate places.
NatHERS Heating and Cooling Load Limits Standard cover 2022

Publisher
Australian Building Codes Board

Version:  2022.  (Latest)
Short Description
NatHERS compliance pathway for energy efficiency.
AS/NZS 1596:2014 The storage and handling of LP Gas 2014 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Fourth Edition 2014.  (Current)
Short Description
​Sets out requirements and recommendations for the safe storage and handling of LP Gas, in cylinders and bulk tanks.
AS 4100:2020 Steel structures 2020 cover

Publisher
Standards Australia

Version:  Third Edition 2020.  (Current)
Short Description
Specifies minimum requirements for the design and the engineering aspects of fabrication and erection, and modification of steelwork in structures in accordance with the limit states design method.
AS/NZS 3500.1:2021 Plumbing and drainage, Part 1: Water services 2021 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Fourth Edition 2021.  (Current)
Short Description
Specifies requirements for the design, installation and commissioning of cold water services from a point of connection to the points of discharge, and for non-drinking water from a point of connection to the points of discharge.
AS/NZS 1680.1:2006 Interior and workplace lighting, Part 1: General principles and recommendations 2006 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2006.  (Pending Revision)
Short Description
Provides general principles and recommendations for the lighting of building interiors to enhance the performance and comfort of those performing visual tasks; deals with illuminating essential task details, using both artificial light and daylight, while controlling or excluding factors that might cause visual discomfort.
AS/NZS 3500.4:2021 Plumbing and drainage, Part 4: Heated water services 2021 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Fourth Edition 2021.  (Current)
Short Description
Sets out the requirements for the design, installation and commissioning of heated water services using drinking water or rainwater or a combination thereof; includes aspects of the installation from, and including, the valve(s) on the cold water inlet to any cold water storage tank or water heater and the downstream fixtures and fittings; applies to new installations as well as alterations, additions and repairs to existing installations.
AS/NZS 2293.1:2018 Emergency lighting and exit signs for buildings, Part 1: System design, installation and operation 2021 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2018.  (Current)
Short Description
Specifies requirements for the design and installation of emergency lighting and illuminated emergency exit signage systems for buildings. Central battery, single point and self-contained systems are included.
AS/NZS 1680.2.2:2008 Interior and workplace lighting, Part 2.2: Specific applications - Office and screen-based tasks 2008 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2008.  (Pending Revision)
Short Description
Sets out recommendations for the lighting of offices and similar tasks, including screen-based tasks. While the tasks may be commonly performed in interiors called offices’, they may also be performed in other interiors; for example, reading, writing and screen-based tasks frequently occur in most types of interior workplaces.