Skip to main content

Search all content

1 - 10 of 12 results
AS 1720.3:2016 Timber structures, Part 3: Design criteria for timber-framed residential buildings 2016 cover

Publisher
Standards Australia

Version:  First Edition 2016.  (Current)
Short Description
Sets out the design methods, assumptions and other criteria, including uplift forces and racking pressures, suitable for the design of timber-framed buildings constructed within the limitations and parameters of, and using the building practice described in, AS 1684.2, AS 1684.3 and AS 1684.4.
AS/NZS ISO 22846.1:2020 Personal equipment for protection against falls - Rope access systems, Part 1: Fundamental principles for a system of work 2020 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2020.  (Current)
Short Description
This Standard adopts ISO 22846-1:2003, which gives the fundamental principles for the use of rope-access methods for work at height; intended for use by employers, employees and self-employed persons who use rope-access methods, by those commissioning rope-access work and by rope-access associations.
AS/NZS ISO 22846.2:2020 Personal equipment for protection against falls - Rope access systems, Part 2: Code of practice 2020 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2020.  (Current)
Short Description
This Standard adopts ISO 22846-2:2012, which provides recommendations and guidance on the use of rope access methods for work at height and expands on the fundamental principles given in AS/NZS ISO 22846.1, in conjunction with which it is intended to be used; intended for use by employers, employees and self-employed persons who use rope access methods, by those commissioning rope access work and by rope access associations.
AS/NZS 1891.4:2009 Industrial fall-arrest systems and devices, Part 4: Selection, use and maintenance 2009 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2009.  (Pending Revision)
Short Description
Specifies requirements and sets out recommendations for the selection, safe use and maintenance of industrial fall-arrest systems and devices based on the use of safety harnesses, horizontal life lines and rails, fall-arrest devices, and associated lanyards, connectors, anchorages and fittings.
AS 1684.4-2010 Residential timber-framed construction, Part 4: Simplified - Non-Cyclonic Areas 2010 cover

Publisher
Standards Australia

Version:  Fourth Edition 2010.  (Pending Revision)
Short Description
Specifies requirements for the building industry with procedures that can be used to determine building practice, to design or check construction details, and to determine member sizes, and bracing and fixing requirements for timber-framed construction in non-cyclonic wind classifications N1 and N2. Also referred to as the timber framing code.
AS 1657:2018 Fixed platforms, walkways, stairways and ladders - Design, construction and installation 2018 cover

Publisher
Standards Australia

Version:  Fifth Edition 2018.  (Current)
Short Description
Sets out requirements for the design, selection, construction and installation of fixed platforms, walkways, stairways and ladders that are intended to provide safe access to places used by operating, inspection, maintenance and servicing personnel.
AS 1684.2:2021 Residential timber-framed construction, Part 2: Non-cyclonic areas 2021 cover

Publisher
Standards Australia

Version:  Fourth Edition 2021.  (Current)
Short Description
This Standard specifies requirements for building practice and the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class 1 and Class 10 buildings as defined by the National Construction Code; the provisions of this Standard also apply to alterations and additions to such buildings; this Standard is to be used in conjunction with the Supplements to this Standard.
AS 2865-2009 Confined spaces 2009 cover

Publisher
Standards Australia

Version:  Third Edition 2009.  (Pending Revision)
Short Description
Sets out the requirements and risk control measures for ensuring the safety of those who must enter or carry out tasks associated with a confined space; contains sections dealing with planning and implementing entry to a confined space; appendices include guidance for training, risk assessment, atmospheric monitoring and sample forms and permits associated with confined space work.
AS 1684.3:2021 Residential timber-framed construction, Part 3: Cyclonic areas 2021 cover

Publisher
Standards Australia

Version:  Fourth Edition 2021.  (Current)
Short Description
Provides the building industry with procedures that can be used to determine building practice, to design or check construction details, and to determine member sizes, and bracing and fixing requirements for time-framed construction in cyclonic area.
AS 3959:2018 Construction of buildings in bushfire-prone areas 2018 cover

Publisher
Standards Australia

Version:  Fourth Edition 2018.  (Current)
Short Description
Specifies requirements for the construction of buildings in bushfire-prone areas in order to improve their resistance to bushfire attack from burning embers, radiant heat, flame contact and combinations of the three attack forms.