1 - 10 of 20 results
AS/NZS 3666.1:2011 Air-handling and water systems of buildings - Microbial control, Part 1: Design, installation and commissioning 2011 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Third Edition 2011.  (Pending Revision)
Short Description
Specifies minimum requirements for the design, installation and commissioning of air-handling and water systems of buildings for the purposes of microbial control. It does not include requirements for refrigerated room airconditioners and non-ducted split systems.
AS 1668.4-2012 The use of ventilation and airconditioning in buildings, Part 4: Natural ventilation of buildings 2012 cover

Publisher
Standards Australia

Version:  Fourth Edition 2012.  (Pending Revision)
Short Description
Sets out minimum design requirements for natural ventilation systems that ventilate enclosures and requirements for the ventilation of car parks.
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location 2001 cover

Publisher
Standards Australia

Version:  Sixth Edition 2001.  (Current)
Short Description
Specifies the criteria for the selection of portable fire extinguishers and the requirements for their application, location and distribution.
AS 4254.2-2012 Ductwork for air-handling systems in buildings, Part 2: Rigid duct 2012 cover

Publisher
Standards Australia

Version:  First Edition 2012.  (Pending Revision)
Short Description
Sets out requirements for materials, construction, and installation, including some aspects of performance, for ductwork for air-handling systems in buildings and facilities, including systems designed in accordance with requirements of AS/NZS 1668.1 and AS 1668.2.
AS 1670.3:2018 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 3: Fire alarm monitoring 2018 cover

Publisher
Standards Australia

Version:  Fourth Edition 2018.  (Current)
Short Description
Specifies the requirements for fire alarm monitoring systems between the monitored fire detection and alarm system and the fire dispatch centre and includes requirements for the monitoring equipment.
AS 1670.4:2018 Fire detection, warning, control and intercom systems - System design, installation and commissioning, Part 4: Emergency warning and intercom systems 2018 cover

Publisher
Standards Australia

Version:  Third Edition 2018.  (Current)
Short Description
Specifies the design, installation and commissioning requirements for emergency warning systems and emergency intercom systems used in buildings for the evacuation of building occupants in the event of a fire or other type of emergency.
AS 3999:2015 Bulk thermal insulation - Installation 2015 cover

Publisher
Standards Australia

Version:  Second Edition 2015.  (Current)
Short Description
Sets out requirements on installing insulation in both new dwellings during construction and the retrofitting of insulation in existing buildings.
AS/NZS 2107:2016 Acoustics - Recommended design sound levels and reverberation times for building interiors 2016 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2016.  (Current)
Short Description
Recommends design criteria for conditions affecting the acoustic environment within building interiors to ensure a healthy, comfortable and productive environment for the occupants and the users.
AS 1191-2002 Acoustics - Method for laboratory measurement of airborne sound transmission insulation of building elements 2002 cover

Publisher
Standards Australia

Version:  Third Edition 2002.  (Current)
Short Description
Provides a method for the measurement of airborne sound reduction index to building partitions such as walls, floor/ceiling assemblies, doors, windows and other space dividing elements.